Shop
AD-4212F
The AD-4212F series brings the precision of high-end laboratory analytical balances to production lines/systems, glove boxes and fume cupboards with unprecedented flexibility and utility. High Resolution, High Stability & Space saving.
Highlights
Features
Downloads
Highlights
- Weighing Data Simulator (WDS) that visualizes the effect of each change to response characteristics settings for comparison
- Impact shock detection (ISD) to prevent error-causing and potentially damaging impact loads to the weight sensor
- IP65 dust and waterproof for protection from spillage of powder or liquid materials
- Fast stabilization of approx. 0.5 seconds (typical) for up to 300 g excluding tare
- Smart-range function that provides a readability of 0.001 g for up to 510 g even after tare has been performed
- Quick, automatic precision assessment using the electronically controlled load (ECL)
- Space-saving with an integrated A/D converter that enables direct connection to a PC/PLC
- Adaptable to a user-designed, special weighing pan/jig
- Shock logging function that records up to 50 adverse impact loads with a timestamp for later inspection
- Customizable response characteristics settings using the free dedicated software WinCT-AD4212F
- Communication interface that supports RS-485 for daisy-chain connection of multiple weigh modules as well as RS-232C
- Embedded terminating resistor
- Configurable data transmission rate by changing the baud rate
- Diverse peripherals available for conversion between RS-232C and a different interface/output
Features
Model | AD-4212F-6203D | AD-4212F-10202 | AD-4212F-22001 |
Capacity | 510 g / 6200 g*i | 10200 g | 22000 g |
Readability (d) | 0.001 g / 0.01 g*i | 0.01 g | 0.1 g |
Repeatability (standard deviation) |
0.002 g / 0.01 g | 0.01 g | 0.1 g |
Linearity | ±0.02 g | ±0.03 g | ±0.2 g |
Stabilization time*ii | d = 0.001 g : 1.3 secs d = 0.01 g : 1.0 sec |
0 to 300 g : 0.5 secs 300 to 10200 g : 1.0 sec |
0 to 300 g : 0.5 secs 300 to 22000 g : 1.0 sec |
Sensitivity drift (10 to 30 °C) | ±2 ppm/ °C | ±3 ppm/ °C | |
Weighing pan size | 70 × 70 mm |
*1 Smart range function: The display will switch to the standard range automatically when the value exceeds 5.1g but will return to the precision range when RE-ZERO (tare) is performed.
Options & Accessories | Model |
---|---|
Static eliminator | AD-1683 |
Electrostatic field meter | AD-1684A |
Compact printer | AD-8127 |
Remote controller and display unit | AD-8922A |
Remote controller (BCD) | AD-8923-BCD |
Remote controller (CC-link) | AD-8923-CC |
RS-232 cable (10m, for A&D’s external display)*** | AX-KO3590-1000 |
AX-KO4472-1000: RS-232C cable (10m, for a PC/PLC) | AC-KO4472-1000 |
*** A 2m cable is provided as standard
Downloads
Highlights
- Weighing Data Simulator (WDS) that visualizes the effect of each change to response characteristics settings for comparison
- Impact shock detection (ISD) to prevent error-causing and potentially damaging impact loads to the weight sensor
- IP65 dust and waterproof for protection from spillage of powder or liquid materials
- Fast stabilization of approx. 0.5 seconds (typical) for up to 300 g excluding tare
- Smart-range function that provides a readability of 0.001 g for up to 510 g even after tare has been performed
- Quick, automatic precision assessment using the electronically controlled load (ECL)
- Space-saving with an integrated A/D converter that enables direct connection to a PC/PLC
- Adaptable to a user-designed, special weighing pan/jig
- Shock logging function that records up to 50 adverse impact loads with a timestamp for later inspection
- Customizable response characteristics settings using the free dedicated software WinCT-AD4212F
- Communication interface that supports RS-485 for daisy-chain connection of multiple weigh modules as well as RS-232C
- Embedded terminating resistor
- Configurable data transmission rate by changing the baud rate
- Diverse peripherals available for conversion between RS-232C and a different interface/output
Features
Model | AD-4212F-6203D | AD-4212F-10202 | AD-4212F-22001 |
Capacity | 510 g / 6200 g*i | 10200 g | 22000 g |
Readability (d) | 0.001 g / 0.01 g*i | 0.01 g | 0.1 g |
Repeatability (standard deviation) |
0.002 g / 0.01 g | 0.01 g | 0.1 g |
Linearity | ±0.02 g | ±0.03 g | ±0.2 g |
Stabilization time*ii | d = 0.001 g : 1.3 secs d = 0.01 g : 1.0 sec |
0 to 300 g : 0.5 secs 300 to 10200 g : 1.0 sec |
0 to 300 g : 0.5 secs 300 to 22000 g : 1.0 sec |
Sensitivity drift (10 to 30 °C) | ±2 ppm/ °C | ±3 ppm/ °C | |
Weighing pan size | 70 × 70 mm |
*1 Smart range function: The display will switch to the standard range automatically when the value exceeds 5.1g but will return to the precision range when RE-ZERO (tare) is performed.
Options & Accessories | Model |
---|---|
Static eliminator | AD-1683 |
Electrostatic field meter | AD-1684A |
Compact printer | AD-8127 |
Remote controller and display unit | AD-8922A |
Remote controller (BCD) | AD-8923-BCD |
Remote controller (CC-link) | AD-8923-CC |
RS-232 cable (10m, for A&D’s external display)*** | AX-KO3590-1000 |
AX-KO4472-1000: RS-232C cable (10m, for a PC/PLC) | AC-KO4472-1000 |
*** A 2m cable is provided as standard